Failsafe
The help for this page of the Version 2 transmitter, as its latest update shows it. On the transmitter, Animation at the top of this help page plays a short film of the page in use.
On the transmitter: Model setupFailsafe
Choose where the controls go if the receiver loses the signal.
To set it
- Switch the model on, and connect.
- Tick the channels that should go to a set position.
- Put the sticks and switches where the model should go, with the motor switched off.
- Hold them there, and press 'Save'.
'All' ticks every channel. 'None' clears them all.
'OK' keeps the ticks and goes back to 'Model setup'.
With the motor off, the throttle is saved at 'Motor off value'.
The positions are saved IN THE RECEIVER.
So 'Save' works ONLY WHILE CONNECTED.
If not, it says 'No model is connected.' and saves nothing.
'Save' also sends the ticks.
After changing them, press 'Save' again.
What happens
While the receiver hears nothing, it holds the last positions. A gap of under three seconds changes nothing.
After about three seconds it moves the controls to the saved positions, and the transmitter says the model is disconnected.
When the signal comes back, full control returns.
(A Version 1 receiver, and Version 2 firmware before 0.9.922, wait one and a half seconds.)
Which receivers use the ticks
A Version 1 receiver moves only the ticked channels.
The others stay where they were.
A Version 2 receiver on 0.9.885 or later moves only the ticked channels too. Older Version 2 firmware moves all 16:
there, hold EVERY stick and switch where it should be when you press 'Save'.
A Version 2 receiver that sends CRSF to a flight controller (Rotorflight) does not use these positions.
The flight controller's own failsafe takes over: set it there.
Still stuck?
See common questions, or write to mmessiter@gmail.com. Say which page, and what the screen showed.